TITEBOND 675 LVT FLOORING ADHESIVE

Titebond 675 is a low odor acrylic polymer adhesive designed to produce a strong tenacious bond to oily or highly plasticized LVT products. Titebond 675 provides a strong and permanent bond on heavy traffic areas including commercial, institutional and industrial installations. It may be used for indoor installations over standard construction surfaces including LVT/Plank, cork underlayment, solid vinyl/rubber sheet goods & stair treads. Titebond 675 is perfect for pressure sensitive installations using trowel or roll method. It can also be used in a wet lay method. Titebond 675 contains no volatile solvents, hazardous materials or carcinogens, and it will not promote plasticizer migration. It is non-flammable, non-toxic and has no unpleasant or lingering odor. Titebond 675 provides the professional installer with a fast setting, water-resistant and environmentally-safe adhesive.

Features & Benefits


  • LEED V4.1 CERTIFIED
  • Extra strength for hard to bond LVT
  • Can be rolled for pressure sensitive applications
  • Fast Setting
  • Designed for Use with Hard to Bond LVT and Highly Plasticized LVT
  • Ideal for LVT/Plank, Cork Underlayment, Solid Vinyl/Rubber Sheet Goods & Stair Tread
  • Strong Durable Bond
  • Guaranteed Against Discoloration
  • May be Used for Indoor Installations Over Standard Construction Surfaces
  • Provides a strong, permanent bond to LVT/plank, cork underlayment, solid vinyl/rubber sheet goods & stair tread
  • Non-flammable
  • Water-resistant
  • Environmentally safe

Application Guidelines


  • Floor Covering Recommendations: Luxury vinyl tiles (LVT)/Plank, solid vinyl/rubber flooring and stair treads. For use on exterior grade plywood, Group 1, other underlayments approved by manufacturers, concrete, cementitious flattening materials, primed lightweight concrete and well bonded VCT, sheet goods or ceramic tiles all deglossed. Adhesive provides a strong, permanent bond on heavy traffic areas including commercial, institutional and industrial installations.
  • Subfloor Preparation: All substrates must be clean, dry, structurally sound, properly cured and free of dirt, oil, paint, old adhesive, wax, sealers and curing agents. General scouring with 20 grit or #3 1/2 open-coat sandpaper will remove most compounds. All loose materials must be vacuumed from the surface after scouring. The subfloor must be flat to a tolerance of 3/16” in a 10’ radius. Grinding concrete floors is preferred over the use of filling compounds. If filling/flattening compounds are used, they must be Portland cement based and have a compressive strength equal to or greater than 3000 psi when cured. Moisture level in concrete subfloor will fluctuate. Any cementitious material used must be rated for the highest moisture content possible. Consult the cementitious material manufacturer’s application directions. Use of product over light weight concrete and all gypsum based materials requires the use of Titebond Concrete Primer or equivalent prior to application of adhesive.
  • Subfloor Moisture Check: Titebond 675 is not to be used where excessive moisture and alkalinity limitations are exceeded. All concrete slabs should tested for moisture per ASTM F2170 to determine RH and placed in strict accordance with applicable specifications and standards. Do not use this product when temperature of the substrate is below 65ºF or above 85ºF when the relative humidity exceeds 65%. Concrete should be fully cured (at least 45 days) and without hydrostatic pressure. Titebond 675 should not be used on slabs treated with sealers or curing compounds, wet, dusty, contaminated or friable substrates. Titebond 675 may be used on slabs up to 99% RH. Flooring must be acclimated per manufacturers guidelines. When installing directly over wood subfloors the moisture content of the subfloor should be 13% or less. Installation over single layer wood subfloors is not recommended.
  • Installation: Wet Lay Method - Porous Substrates: Adhesive must transfer to backing to promote optimum adhesion in wet lay applications. Employ a 100 lb. roller in both directions within one hour of installation to work out any air pockets and produce solid bonding.
  • Installation: Pressure Sensitive Method - Non-Porous Substrates: Titebond 675 has the ability to be rolled or troweled for use as a pressure sensitive adhesive. When using a 3/8” nap for rolled application, coverage will be approximately 150–200 square feet per gallon, depending on the amount of pressure used to apply the adhesive. The adhesive offers adequate strength to bond an LVT floor in a pressure sensitive application. Allow adhesive to dry until a firm touch does not transfer adhesive. When using a 1/16” x 1/32” x 5/64” trowel, coverage will be approximately 250 to 300 sq. ft. per gallon. Spread adhesive and let it become dry to touch, where there is no transfer to fingers. This will take approximately 35-90 minutes depending on temperature and humidity, or about 15 minutes with a fan assist. Do not install floor before adhesive is ready. Installing flooring too soon can lead to slippage and gaps between pieces. Install LVT per manufacturer’s directions with no more than three hours of open time. Keep the adhesive free from dust and dirt during long open times. Dust and dirt will negatively affect strength. KEEP FROM FREEZING: Acclimate product to room temperature 24 hours prior to installation.
  • Cleanup: Clean wet adhesive with water or Titebond Adhesive Remover Cleaning Wipes. Clean dry adhesive with mineral spirits, and follow solvent vendor’s safety precautions.

Trowel Recommendations and Coverage

FLOORING TYPE TROWEL SIZE TROWEL TYPE COVERAGE
LVT / PLANK, SOLID VINYL / RUBBER & STAIR TREADS 1/16" SQUARE-NOTCH APPROXIMATELY 150 SQ. FT. PER GALLON
CORK UNDERLAYMENT 1/16" SQUARE-NOTCH APPROXIMATELY 150 SQ. FT. PER GALLON
LVT / PRESSURE SENSITIVE 1/16" X 1/32" X 5/64" U-NOTCH APPROXIMATELY 250 to 300 SQ. FT. PER GALLON
  ROLLER - 3/8" NAP APPROXIMATELY 150 to 200 SQ. FT. PER GALLON
CLEAN TROWEL WITH WATER OFTEN TO PREVENT ADHESIVE BUILD-UP.

Physical Properties


  • Type: Latex
  • Calculated VOC: 19.79 g/L
  • Color: Beige
  • Weight Per Gallon: 10.4 lbs.
  • Solids: 71%
  • Viscosity: Trowel Grade
  • Flashpoint: > 200°F (Pensky-Martens Closed Cup)
  • Freeze / Thaw Stability: Stable (5 cycles at 20° F.)
  • Storage Life: 24 months in tightly closed containers.

Limitations


MOISTURE CONTENT LIMITATIONS: Titebond 675 is not to be used where excessive moisture and alkalinity limitations are exceeded. All concrete slabs should tested for moisture per ASTM F2170 to determine RH and placed in strict accordance with applicable specifications and standards. Do not use this product when temperature of the substrate is below 65ºF or above 85ºF when the relative humidity exceeds 65%. Concrete should be fully cured (at least 45 days) and without hydrostatic pressure. Titebond 675 should not be used on slabs treated with sealers or curing compounds, wet, dusty, contaminated or friable substrates. Titebond 675 may be used on slabs up to 99% RH. Flooring must be acclimated per manufacturers guidelines. When installing directly over wood subfloors the moisture content of the subfloor should be 13% or less. Installation over single layer wood subfloors is not recommended.

Do not use over high alkaline concrete (over 9.0 pH). Do not use to bond two non-porous substrates unless using pressure sensitive method. Product must dry to build strength. Do not store below freezing. Use in well-ventilated area. Warranty covers subfloor moisture resistance but does not cover damage from flooding or other surface moisture contamination.

CAUTION: Do not sand, scour or abrade any material that is suspected of containing asbestos fibers. Asbestos is known to cause cancer. Federal law requires that asbestos be handled by a licensed and certified hazardous materials contractor.

Product SKUs


Part NumberUPCCase UPCSizeWeightUnits Per PackagePackages Per Pallet
9254037083092547100370830925444 Gallon Plastic Pail44.00136
925603708309256110037083092568Gallon Plastic Pail45.00430

Caution Statement


WARNING: EYE AND SKIN IRRITANT. Do not swallow. Do not allow eye contact or prolonged skin contact. FIRST AID:If swallowed, do not induce vomiting, contact physician. If eye contact occurs, flush eyes with water for 15 minutes. Wash skin contact areas with soap and water. If irritation from eye or skin contact areas persist, contact physician. For additional information, refer to Safety Data Sheet.
KEEP OUT OF THE REACH OF CHILDREN.

Warranty Statement


Franklin International will honor the applicable terms of any resilient floor manufacturer’s current published adhesive warranty or subfloor moisture warranty (where applicable) when the flooring was installed using Titebond 675 LVT Flooring Adhesive in accordance with product instructions and the instructions of the resilient floor manufacturer.*

Franklin International will also warrant Titebond 675 to be free from defects in materials and workmanship for a period of one year from the date of manufacture, if the product has been installed in accordance with the Franklin Specification Guide and the installation instructions furnished with the product. In the event of loss of adhesion of Titebond 675 due to product defect, Franklin International will reimburse the customer for the cost of labor and materials necessary to repair or replace the affected area(s) of the installed resilient flooring.

* Any and all addendums or changes to the vinyl floor manufacturer’s warranties will be reflected in the execution of Franklin International’s warranty immediately upon release by the vinyl floor manufacturer. The effective date of said changes and addendums will dictate coverage by Franklin International in relations to the date of installation.

As Franklin International is honoring the applicable terms of all vinyl floor manufactures’ current published warranties, Franklin International will also require the same jobsite preparations and installation instructions that accompany each warranty in question.

Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Since the use of this product is beyond the control of the manufacturer, no guarantee or warranty, expressed or implied, is made as to such use or effects incidental to such use, handling or possession or the results to be obtained, whether in accordance with the directions or claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.

2020 Bruck Street, Columbus, Ohio 43207
CUSTOMER SERVICE 1-800-669-4583
TECH SERVICE 1-800-347-4583
www.titebond.com

Franklin International